Genorama coated microarray slides
Genorama® high
quality glass microarray slides are developed and tested primarily for DNA-based applications, however, nucleic acids, proteins, small molecules,
cells and extractscan also be immobilized. The activated glass slides are produced under
rigorous quality control and tested for low background and good immobilization
characteristics. As a result, the slides have a very clean and uniform surface,
highly suitable for printing top quality microarrays.
Two surface coatings are available
|
Type |
SAL |
SA |
|
Coating |
aminosilane with linker |
aminosilane |
|
For binding |
short aminated DNA |
unmodified DNA, long aminated DNA |
|
Molecule length |
8-75-mer oligonucleotides |
Up to 1 kb |
|
Type of binding |
Covalent bond |
Non-covalent bond |
|
Buffer |
Genorama® Spotting Solution ITM |
Genorama® Spotting Solution IITM |
The slides produced in two
formats: standard size slides 25 x 75 x 1 mm and thin slides 24 x 60 x 0.15 mm
(also known as coverslips).
Six different slide types are available
|
Code |
Coating |
W x L x H mm |
CAT # |
|
For binding aminated DNA |
|
|
|
|
SAL -1 |
3-Aminopropyltrimethoxysilane+ 1,4-Phenylenediisothiocyanate |
25x75x1.0 |
G30111 |
|
SAL -1 ULTRA* |
3-Aminopropyltrimethoxysilane+ 1,4-Phenylenediisothiocyanate |
25x75x1.0 |
G30131 |
|
SAL -0.1** |
3-Aminopropyltrimethoxysilane+ 1,4-Phenylenediisothiocyanate |
24x60x0.15 |
G30121 |
|
For binding unmodified DNA |
|
|
|
|
SA -1 |
3-Aminopropyltrimethoxysilane |
25x75x1.0 |
G30011 |
|
SA - 1 ULTRA*** |
3-Aminopropyltrimethoxysilane |
25x75x1.0 |
G30031 |
|
SA -0.1 |
3-Aminopropyltrimethoxysilane |
24x60x0.15 |
G30021 |
* - same chemistry as the SAL, only the slide
substrate is of higher quality level with optically flat surface.
** - 24 x 60 mm slides have one specially refined edge to ensure maximum
uniformity of light distribution via total internal reflection excitation in
the Genorama® QuattroImagerTM.
*** - same chemistry as the SA, only the slide
substrate is of higher quality level with optically flat surface.
SAL advantages compared to epoxy slides:
1. SAL slides have at least 2 times better binding capacity of aminated DNA than epoxy coated slides.
2. As SAL slides are more reactive, the probe immobilization time to SAL is much shorter; (only 2 hours for SAL coating, 24 hours for epoxy slides)
3. Lower pH of the printing solution. (epoxy – pH over 11.0 required to activate the surface. SAL – pH 9.0)
4. Due to the linker molecule binding occurs further from the surface, theoretically leaving more space for target hybridization.
Additional information
Slides are packed in boxes of 25. Slides
sealed in an alufoil bag to protect the activated surface from light and
maintain a stable storage environment. Printed slides can be stored at 4°C for
up to 6 months. Genorama also provides bar-coded slides upon request.
Genorama strongly recommends the use of Genorama®Spotting Solutions together with the SAL and SA slides in order to ensure
proper quality.